FreeStyle Precision Pro

Blood Glucose and β-Ketone Monitoring Meter

The first1 blood glucose monitoring system designed for the hospital with Triple Protection. Safeguard the integrity of your hospital’s blood glucose and ketone point-of-care testing process with the FreeStyle Precision Pro system.

 

Freestyle Optium Neo H
Freestyle Optium Neo H
Freestyle Optium Neo H

Features & Benefits

Real-time2 dual-band wireless
communication

 

 

Immediate patient test results when and where you need them to keep your patient records up to date.

✓ Rapid access to test results anywhere2 in the hospital

✓ Streamlined workflow – no docking required

✓ Dual-band wireless for more connectivity options3

✓ Automatic upload of patient results to electronic medical records4

✓ Real-time data sharing2

2-D barcode

technology

 

 

Helps improve safety, efficiency and creates better patient ID tracking.

✓ Reads 1D and 2D barcodes enabling transition to new technology

✓ Camera based reader eliminates risk of laser eye contact

✓ 2D barcodes are easily scanned on curved patient wristbands5

✓ Store more information in less space with 2D barcodes6

Improved accuracy and haematocrit performance

 

 

Helps enhance bedside accuracy for better patient care.

✓ Meets current ISO15197 standards

✓ Haematocrit compensation from 15%–65% enhances accuracy

✓ In clinical studies, 100% of results with FreeStyle Precision Pro glucose test strips were within ±0.83 mmol/L of laboratory reference for glucose concentration <5.6 mmol/L and >99% within ±15% for glucose concentration ≥5.6 mmol/L

 within ±0.28 mmol/L
or ±5% of lab reference
within ±0.56 mmol/L or ±10% of lab referencewithin ±0.83 mmol/L
or ±15% of lab reference
Glucose concentrations
<5.6 mmol/L (capillary)
61.3% (136/222)95% (211/222)100% (222/222)
Glucose concentrations
≥5.6 mmol/L (capillary)
70.8% (532/751)95.5% (717/751)99.1% (744/751)

        

Individually foil-
wrapped test strips

 

 

Minimises the risk of exposure to pathogens for increased safety.

✓ 5-second blood glucose test time for fast bedside results

✓ Protected from the air, humidity and other contaminants to ensure accurate results7,8

✓ Designed with convenient automatic calibration and expiry date check to guarantee reliable results via the individual barcode

✓ Quick and easy to open due to notched foil wrapper

✓ Individually barcoded to enable ‘Automatic Lockout’, which prevents inaccuracies that can occur due to the use of expired test strips*

✓ In hospital studies, 25.7%–57.0% of vial packaged blood glucose test strips were contaminated with bacteria, posing risk of bacterial transmission between patients9,10

 

Also includes an on-meter display that shows patient and operator ID confirmation for increased safety.

References & Disclaimers

Images are for illustrative purposes only. Not real patient or data.

1. Based on leading brands – Abbott Diabetes Care, Roche Diagnostics, and Nova Biomedical.

2. In a WiFi enabled facility when the meter and data management systems are properly configured.

3. More connectivity options compared to single-band systems.

4. Requires integration with hospital medical records (EMR) system.

5. Sharman P, Bedside barcoding for the blood bank, Medical Laboratory Observer, January 2007;39:18–9.

6. Hattie M., Barcoding: Labs go 2D, Medical Laboratory Observer, September 2009 [http://www.mlo-online.com/features/2009_september/0909_bar_codes.pdf].

7. Silverman BC et al. Operational errors cause inaccurate glucose results. Diabetes Care 2000; 23:429–430.

8. Bamberg R et al. Effects of adverse storage conditions on performance of glucometer test strips. Clin Lab Sci 2005; 18:203–209.

9. Vanhaeren S et al. Bacterial contamination of glucose test strips: Not to be neglected. AJIC 2011; 39 (7):611–613.

10. Pérez-Ayala M et al. Prevalence of bacterial contamination of glucose test strips in individual single-use packets versus multiple-use vials. J Diabetes Sci Technol. 2013; 7(4):854–862.

* Decide whether an operator can continue to test (‘allow test’ or ‘warn’) or not (‘lockout’) when a strip lot is scanned or entered to the meter for a lot of strips that is not on the approved strip lot list. The maximum number of strip lots that can be downloaded to the FreeStyle Precision Pro meter is 36: 18 Glucose and 18 Ketone. 

 

ADC-94300 v2.0

Loading...