FreeStyle Libre 2 system
FreeStyle Libre 2 system
FreeStyle Libre 2 system

Advanced technology designed to fit into your patients’ lives. 

FreeStyle Libre 3 is a continuous glucose monitoring (CGM) system that streams minute-to-minute glucose readings directly to your patients’ smartphones,2 enabling patients to act faster to reduce hypoglycaemia.

FSL3 CGM FSL3 CGM

Performance your patients can count on

Glucose readings every minute of every hour of every day for up to 14 days 

5x more readings power up to 5x faster alarms8

Patients can view their minute-to-minute glucose data with a quick glance of their smartphones2

The world’s smallest, thinnest5, and
most discreet6 sensor

Sensor / The FreeStyle Libre 3 sensor is smaller than the size of two stacked 5-cent Euro coins

Discreet

Smaller than the size of two stacked 5-cent Euro coins, easy to wear6 with a discreet6 sensor for up to
14 days.

Patients simply scan to activate the sensor – no finger pricking or code entry is required.

Easy

The sensor is easy to apply6 using a one-piece applicator. It requires no in-person training to use.

The sensor can be worn while patients shower, swim and exercise.7

5x more reading power up to 5x faster alarms8,9

The sensor sends glucose readings directly to patients’ smartphones2 every minute to provide complete glycaemic profiles**, so you can make informed treatment decisions.

Minute-to-minute readings, enable your patients to act faster to reduce hypoglycaemia

Graph showing blood glucose in recommended range over time.

38%

38% reduction in time spent in hypoglycaemia without increasing A1c10

Graph showing blood glucose in recommended range over time.

40%

40% reduction in nocturnal hypoglycaemia10

Graph showing blood glucose in recommended range over time.

50%

50% reduction in serious hypoglycaemia (≤3.0 mmol/L)10

Excellent, reliable glucose alarms so your patients' caregivers have peace of mind 18,9

The fully customisable glucose alarms allow users to set high and low glucose alarm thresholds, based on individual needs and preferences. Alarms let patients know the minute they’ve crossed the preset thresholds, allowing them to take action to manage their glucose levels.

Three optional sound/vibration alarms alert patients to:

FSL3 App FSL3 Reader
  • Low glucose levels 
  • High glucose levels 
  • Signal loss 

 

50 % Wider range between sensor and smartphone17

Patients stay connected to readings and alarms out to 10 meters—the strongest CGM connection offered.17 In the event of signal loss, the system reconnects in just 30 seconds6 on average, so patients won't miss a possible hypo. 14-day sensor data storage means no data gaps in recording. 

The FreeStyle Libre 3 system has a range of 10 metres, compared to 6 metres for other leading brands The FreeStyle Libre 3 system has a range of 10 metres, compared to 6 metres for other leading brands

Significant improvement in clinical outcomes11 and quality of life12

As the most accurate 14-day continuous glucose monitoring system13, FreeStyle Libre 3 empowers patients to act faster
to avoid hypoglycaemia. It can help reduce time spent in hypoglycaemia10,14 and improve overall glucose control for patients.11,15  Find out more about the accuracy and reliability of the FreeStyle Libre 3 system.

fsl3

95% of patients have a better understanding of their glucose fluctuations12


 
 

fsl3

1hr more in Time in Range per
day compared to finger
pricking10



 

fsl3

0.55% reduction of A1c at at
2-4 months and sustained at
month 12 in adults and
children with T1D and adults
with T2D.11

NOTE: statistically significant A1c reduction based on the confidence interval range.

Studies data collected with FreeStyle Libre system and are applicable to the FreeStyle Libre 3 system based on technological similarities.

Comprehensive glycaemic reports in LibreView16

Graph showing blood glucose in recommended range over time.

Quickly assess your patient’s Time In Ranges in a single-page, comprehensive report

Graph showing blood glucose in recommended range over time.

Provides further details, treatment, and personalised medication considerations to help you manage your patient’s diabetes

Graph showing blood glucose in recommended range over time.

A quick overview of your patient’s daily insulin usage to help make treatment adjustments

   

References & Disclaimers

1. Data on file, Abbott Diabetes Care, Inc. Based on the number of users worldwide for the FreeStyle Libre portfolio compared to the number of users for other leading personal use sensor-based glucose monitoring systems.

2. The FreeStyle Libre 3 app is only compatible with certain mobile devices and operating systems. Please see check our website for more information about device compatibility before using the app. Sharing of glucose data requires registration with LibreView.
3. Based on signal range in Dexcom G6 CGM User Guide and Medtronic Guardian Connect System User Guide.

4. Hilliard, M., et al. Diabetes Technology & Therapeutics. (2019): https:/doi.org/10.1089/dia.2019.0142

5. Among patient-applied sensors.

6. Data on file, Abbott Diabetes Care, Inc.

7. Sensor is water-resistant up to 1 meter of water. Do not immerse longer than 30 minutes.
8. Dexcom G6 CGM User Guide and Medtronic Guardian Connect System User Guide.
9. Notifications will only be received when alarms are turned on and the sensor is within 10 meters unobstructed of the reading device.
10. Bolinder, J. et al. Lancet (2016): http://doi.org/10.1016/S0140-6736(16)31535-5.

11. Evans, M. et al. Diabetes Ther (2020): https://doi.org/10.1007/s13300-019-00720-0.

12. Fokkert, M. et al. BMJ Open Diab Res Care (2019): https://doi.org/10.1136/bmjdrc-2019-000809.

13. Alva, S. et al. Diabetes Ther. (2023); doi: 10.1007/s13300-023-01385-6.
14. Haak, T. et al. Diabetes Ther. (2017): https://doi.org/10.1007/s13300-016-0223-6.
15. Yaron, M. et al. Diabetes Care (2019): https://doi.org/10.2337/dc18-0166.

16. The LibreView data management software is intended for use by both patients and healthcare professionals to assist people with diabetes and their healthcare professionals in the review, analysis and evaluation of historical glucose device data to support effective diabetes management. The LibreView software is not intended to provide treatment decisions or to be used as a substitute for professional healthcare advice.
17. Based on the signal strength Dexcom G6 CGM User Guide and Medtronic Guardian Connect System User Guide.
18. Campbell, Fiona, et al. "Outcomes of Using Flash Glucose Monitoring Technology by Children and Young People With Type 1 Diabetes in a Single Arm Study." Pediatric Diabetes 19, no. 7 (November 2018): 1294-

1301. https://doi.org/10.1111/pedi.12735.** Unger, J. et al, Postgrad Med. (2020): https://doi.org/10.1080/00325481.2020.1744393.

 

ADC-97326 v1.0 08/24