FreeStyle Libre 2 System

See patients' complete glycaemic profiles1 with the FreeStyle Libre 2 system

Now with real-time glucose readings sent right to your patients’ smartphones◊,¤ and 15-day wear time with our Libre 2 Plus sensor

Man with FreeStyle Libre 2 Plus sensor checking his phone
Man with FreeStyle Libre 2 Plus sensor checking his phone
Man with FreeStyle Libre 2 Plus sensor checking his phone
 

Managing diabetes with confidence2

The #1 sensor-based glucose monitoring system used worldwide3

With the FreeStyle Libre 2 system, your patients get real-time glucose readings using the LibreLink app◊,¤ to help them manage their diabetes more confidently2 without the need for finger pricks.

FreeStyle LibreLink app with FSL2 logo next to it

Real-time glucose readings 

and alarms every minuteII - designed with safety in mind**

Outstanding accuracy

including low-end accuracy, when it matters most4

Easy connections

Patients can easily share their glucose readings with you and their family members§

Significant outcomes

for T1D5 and T2D6,7

Real-time glucose readings & alarms

Real-time glucose monitoring

  • Glucose levels in interstital fluid continuously measured with the Libre 2 and Libre 2 Plus sensors

  • A reading sent every minute to your patients' smartphones◊,¤ — 1,440 readings per day

Man and woman with the FreeStyle Libre 2 sensor looking at their glucose levels on their phone

Real-time glucose readings anytime, anywhere

with the LibreLink app◊,¤
 

5x more readings power up to 5x faster alarmsǁ

Patients can automatically receive an alarmǁ when their glucose is too low or too high

Meet the Libre 2 sensors

The FreeStyle Libre 2 system is made up of the Libre 2 sensor, Libre 2 Plus sensor and the LibreLink app

The Libre 2 Plus sensor

Our longest lasting sensor and the latest innovation for the FreeStyle Libre 2 system

It conveniently works with the current Libre 2 reader and LibreLink app while extending sensor wear time to 15 days and allows for integrated experiences with insulin pumps.

  • 15-day sensor wear

  • Real-time glucose readings¤,◊

  • Optional glucose alarmsǁ

  • Indicated for ages 2 years and older

FSL2 Plus package

The Libre 2 sensor

Small and discreet, easy to use, and comfortable6 to wear for up to 14 days

With real-time glucose readings automatically sent to your Patients' smartphone◊,¤ and optional alarmsǁ, your patient will always know where their glucose is. Patients can automatically receive an alarmII when their glucose is too low or too high.

  • 14-day sensor wear

  • Real-time glucose readings¤,◊

  • Optional glucose alarmsǁ

  • Indicated for ages 4 years and older

Clean packaging renders are for use in all marketing materials. All language and legal/regulatory icons have been removed for global use.

The packaging approval process differs from the marketing approval process. Any localized packaging renders that appear in marketing collateral must be vetted by the owner of the project to ensure the latest version is used.

Outstanding accuracy8

Both sensors in the FreeStyle Libre 2 system have a high degree of clinical accuracy

with 99.9% of readings in Zones A and B of the Consensus Error Grid4,8 without the need for finger prick calibration

Libre 2 Plus sensor8

  • 8.2% MARD
  • Outstanding accuracy in the low glucose range (<3.9 mmol/L): 98.9% within ±1.1 mmol/L

Libre 2 sensor4

  • 9.2% MARD
  • Outstanding accuracy in the low glucose range (<3.9 mmol/L): 98.4% within ±1.1 mmol/L

Significant outcomes for T1D and T2D

The FreeStyle Libre 2 system is proven to have significant clinical and real-world benefits for patients with T1D and T2D MDIs

Clinical outcomes for T1D5

2.2 hours

more time in range*
vs SMBG at 6 months of use

* Time in Range between 3.9-10.0 mmol/L
SMBG = self-monitored blood glucose

0.5%

reduction in HbA1c*
vs SMBG at 6 months of use

* Primary end point: 0.5% greater HbA1c reduction with the FreeStyle Libre 2 system vs SMBG
SMBG = self-monitored bloog glucose
p<0.001

43 minutes

less time in hypoglycaemia per day*
vs SMBG at 6 months of use

* Hypoglycaemia measured at <3.9 mmol/L
SMBG = self-monitored bloog glucose

Real-world benefits for T2D MDIs

0.9%

A1c reduction on rapid- or
short-acting insulin7

over 3-6 months4
p<0.001

43%

less time in hypoglycaemia per day6 vs SMBG

(p=0.0006)
<3.9 mmol/L

Easy connections

The LibreLink app

Minute to minute glucose readings anytime, anywhere

With the free LibreLink app, real-time glucose readings from the Libre 2 and Libre 2 Plus sensor are automaticallyǁ sent directly to your patients’ smartphone.

LibreView program on a computer screen

LibreView

Glucose data are automatically uploadedΔ from patients’ LibreLink app to LibreView

LibreView is a secure9 cloud-based platform that provides you and your staff access to patient glucose reports to make more informed treatment decisions and support effective diabetes management.

With the LibreLink, patients' glucose readings can be automatically uploadedΔ to LibreView. This means that you can see your patients' complete glycaemic picture to have more informed virtual and in-person treatment conversations. Patients can scan to fill in up to 8 hours of missing data, so your patients’ glucose history is complete.

LibreView program on a computer screen

Additional information

FreeStyle Libre 2 system sensor comparison

 Libre 2 Plus sensorLibre 2 sensor
Wear Time15 days 14 days
PartnershipsIntegration with NovoPen® 6 or NovoPen Echo® Plus None
Glucose Data Transfer
  • Automatically sent to app¤,◊ with option to scan if desired
  • Scan to reader
  • Automatically sent to app¤,◊ with option to scan if desired
  • Scan to reader
For Ages2 years and older*4 years and older*
Sensor Size35 mm (Diameter) x 5 mm (Height)
Comparable to a €2 coin.
35 mm (Diameter) x 5 mm (Height)
Comparable to a €2 coin.
Reader / App CompatibilityLibre 2 reader and LibreLink app
Glucose Reading FrequencyUpdated every 1 minute

Important information for FreeStyle Libre 2 system users

Patients can scan for glucose readings anytime, even during a signal loss

  • A quick scan provides another way for patients to get a glucose reading during Bluetooth®10 interruption

  • Scan to fill in up to 8 hours of missing data, so your patients’ glucose history is complete

  • The only sensor-based glucose monitoring system that can fill in data gaps with a quick scan

For patients without a compatible smartphone

Patients without a device that's compatible with the LibreLink app can use a Libre 2 reader to scan their Libre 2 or Libre 2 Plus sensor. They will benefit from all the features of the FreeStyle Libre 2 system but will not receive real-time glucose readings automatically even if they use the latest version of the FreeStyle LibreLink app as a second device.

Compatible Products

LibreLink App

Real-time glucose readings from the Libre 2 Plus sensor or Libre 2 sensor are automatically¤ updated every minute and sent directly to the LibreLink app on your patients' smartphones.
 

LibreView

Using LibreView, our secure9 cloud-based system, patients can upload their data to share with their doctor and care team. You will be able to access more in-depth reports to support you in making treatment decisions for your patients.

LibreLinkUp

Family members can see the glucose levels of their child or elderly parent right on their smartphone if connected with the LibreLinkUp app.§ 

 

References & Disclaimers

Images are for illustrative purposes only. Not real patient or Health Care Professional or data.

Omnipod and the Omnipod logo are registered trademarks of Insulet Corporation and used with permission.

1. Unger, J. Postgrad Med. (2020): https://doi.org/10.1080/00325481.2020.1744393

2. Fokkert M. BMJ Open Diab Res Care (2019): http://dx.doi.org/10.1136/bmjdrc-2019-000809.

3. Data on file, Abbott Diabetes Care, Inc. Based on the number of users worldwide for the Libre Products compared to the number of users for other leading personal use sensor-based glucose monitoring systems.

4. Alva, S. J Diabetes Sci Technol (2020): https://doi.org/10.1177/1932296820958754.

5. Leelarathna, L. N Engl J Med. (2022): DOI: 10.1056/NEJMoa2205650

6. Haak, T. Diabetes Therapy (2017): https://doi.org/10.1007/s13300-016-0223-6.

7. Kröger J, et al. Three European retrospective real-world chart review studies to determine the effectiveness of flash glucose monitoring on HbA1c in adults with type 2 diabetes. Diabetes Ther 2020;11(1):279–91.

8. Data on file, Abbott Diabetes Care, Inc.

9. LibreView is ISO27001/27018/27701 certified and HITRUST CSF Certified

10. The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Abbott is under license.

◊ The LibreLink app is only compatible with certain mobile devices and operating systems. Please check the website for more information about device compatibility before using the app. Sharing of glucose data requires registration with LibreView.

¤ Glucose readings are automatically displayed in the LibreLink app only when your patients’ smartphone and sensor are connected and in range.

† Finger pricks are required if glucose readings and alarms do not match symptoms or expectations.

‡ 60-minute warm-up required when applying the sensor. *For children aged 4-12 using the FreeStyle Libre 2 or for children aged 2-12 using the FreeStyle Libre 2 plus plus sensor, a caregiver at least 18 years old is responsible for supervising, managing, and assisting them in using the FreeStyle Libre 2 system and interpreting its readings.

** FreeStyle Libre 2 and LibreLink User Manuals

₸ Sensor is water resistant in up to 1 metre (3 feet) of water for a maximum of 30 minutes. Do not immerse longer than 30 minutes. Not to be used above 10,000 feet.

ǁ Notifications will only be received when alarms are turned on and the sensor is within 20ft unobstructed of the reading device.

Δ The user’s device must have internet connectivity for glucose data to automatically upload to LibreView and to transfer to connected LibreLinkUp app users

₼ The LibreView data management software is intended for use by both patients and healthcare professionals to assist people with diabetes and their healthcare professionals in the review, analysis and evaluation of historical glucose device data to support effective diabetes management. The LibreView software is not intended to provide treatment decisions or to be used as a substitute for professional healthcare advice.

§ The LibreLinkUp app is only compatible with certain mobile device and operating systems. Please check www.LibreLinkUp.com for more information about device compatibility before using the app. Use of LibreLinkUp requires registration with LibreView. The LibreLinkUp mobile app is not intended to be a primary glucose monitor: home users must consult their primary device(s) and consult a healthcare professional before making any medical interpretation and therapy adjustments from the information provided by the app.

ADC-77355 v4.0

 

Loading...